Custom battery packs

CUSTOM BATTERY PACKS

Alongside its early mini UPS work, the manufacturer built 18650 lithium battery packs to order for equipment makers — packs specified by the target voltage, capacity and BMS requirement of the device they served. That pack work belongs to the range's earlier catalogue, and the lines it produced are recorded below.

Illustration of battery cells with a cable and connector
12V UPS battery unit with cable

The pack lines, as they were built

12V 6,600 mAh 18650 rechargeable lithium pack. 24V 6 Ah stage-light pack with 10A BMS. 24V 8,800 mAh 18650 pack with 10A BMS. 11.1V/12V 24.2 Ah rechargeable pack. A golf-caddy battery pack built for a 200W electric golf-caddy motor. An intelligent temperature-control 7.4V lithium battery for heated clothing. A 12V UPS battery and a 12V 1A DC online UPS completed the line.

How pack work started

Pack work started from the device, not from a catalogue page: its voltage, its current draw, its connector, and the runtime it needed. Those four facts decided the conversation — which platform the pack built on, which capacity tier it took. Buyers repeating an earlier program should name the pack they are repeating, so the reply can work from the same figures.

The listed packs, device by device

The listings were device-led: a 12V pack for a golf caddy's 200W motor, a 24V pack for a stage light, an 11.1V/12V pack at 24.2Ah — each named for the device it served. Buyers repeating an earlier program should also name the pack they are repeating, so the reply can work from the same figures instead of reconstructing the program from memory.

BMS and the questions that matter

Several of the listed packs were specified with their battery management — a 10A BMS appears against both 24V packs — and the BMS rating remains one of the figures a serious pack inquiry should always carry: it bounds the discharge the pack will deliver and the protection it provides, and it is where underspecified pack programs most often went wrong. State the device's peak draw beside its continuous draw; the BMS is chosen against the peak, the capacity against the continuous, and confusing the two produces a pack that is simultaneously oversized and underprotected.

Related pages

Ask for a quotation

Tell us the model, the output voltages your equipment needs and the quantity band for your order. If you are matching a UPS to a router, camera or terminal, add the device's rated voltage and current.